Transformer products

WILDLIFE PROTECTOR

Monolithic plastic device installed in high voltage insulators of electrical distribution transformers avoiding accidental contact of birds and small animals. Its design allows installation without disconnecting the cables of the transformer; Its tapered top and cutting step signals can adapt different cable[...] See more
 WILDLIFE PROTECTOR

OIL LEVEL PEEPHOLE

Kit to visualize the oil level in the transformers: The kit includes the flange as the main element, the peephole in high mechanical and corrosion resistance polycarbonate with level marks, gasket dielectric oil resistant, and, tapered screws in order for the weld on the tank to be centered in the stamped[...] See more
 OIL LEVEL PEEPHOLE

OVERPRESSURE VALVE

The overpressure valve is used to ease the internal pressure of the tank when it exceeds the safe limits of operation. It doesn’t operate in case that sudden overpression is presented. Chracteristics: Opening pressure: 10 PSI ± 2 reclose pressure: 80% of opening[...] See more
 OVERPRESSURE VALVE

TRANSFORMER RADIATORS

The radiators allows that insulating liquid distributes through them, in all the levels the heat generated by the transformer is transferred to the radiator by the oil and the radiator spreads the heat by the air[...] See more
 TRANSFORMER RADIATORS

BUSHING WELL 200 AMP 35 KV

NOMINAL CURRENT 200 continuous Amp rms Short current standing 10.000 symmetric Amp for 0, 17 sec 3,500 symmetric Amp for 3, 0 sec VOLTAGE Class 35 Kv Maximal phase to ground voltage 21.1 Kv Standing AC voltage 60 Hz during one minute 50 Kv Standing DC voltage during 15 minutes 103 Kv Impulse isolation level BIL and peak full wave 150 Kv Minimum corona discharge voltage 26 Kv Tap Changer Continuous 100 Amp and 60 Amp [...] See more
 BUSHING WELL 200 AMP 35 KV

SECTIONER OR SWITCHERS ON-OFF

The sectioner or switch ON-OFF is used to energize or de-energize the pedestal type transformer or the maneuver box. It’s a device used in the radial pedestal type transformers and it is placed in series with the winding and the high voltage insulators. Externally it has an actioner knob which is placed in the high voltage compartment. It accomplish all the requirements of the norm ANSI/IEEE standard C 37.71 y c 37.72. Nominal Current: 300 Amp rms continuous. Short[...] See more
 SECTIONER OR SWITCHERS ON-OFF

DERIVATION CHANGER 34.5 KV 100 AMP 6 PARTS

The derivation tap changer is a device that allows to select the winding derivation when the transformer is de-energized, to guarantee that in the low voltage side it is given what is needed. Use: Three-phase distribution Transformers Current: are used 6 parts to duplicate the commutator current. Voltage: 15-25 KV Basic insulating level to BIL impulse 150[...] See more
 DERIVATION CHANGER 34.5 KV 100 AMP 6 PARTS

THREE – PHASE DERIVATION TAP CHANGER

The derivation tap changer is a device that allows to select the winding derivation when the transformer is de-energized, to guarantee that in the low voltage side it is given what is needed. Use: in three-phase distribution transformers. Current: 100 Amp continuos-60 Amp continuous. Voltage: 15KV- 25 KV Y 34.5 KV Basic level of insulation to impulse BIL 150 y 200 KV respectively. AC Tension applied to 60 Hz during 1 minute 50 KV Y 70 KV respectively. ICONTEC Norm:[...] See more
 THREE – PHASE DERIVATION TAP CHANGER

DERIVATION TAP CHANGER

The derivation tap changer is a device that allows to select the winding derivation when the transformer is de-energized, to guarantee that in the low voltage side it is given what is needed. Use: single-phase distribution transformers. Current: 100 Amp cpontinuous- 60 Amp continuous Voltage: 15 KV-25 KV Y 34.5 KV Basic level of insulation to the BIL impulse 150 y 200 KV respectively. AC tension applied to 60 Hz during 1 minute 50 KV y 70 kv respectively. ICONTEC[...] See more
 DERIVATION TAP CHANGER

LINEAL DERIVATION CHANGER

Used in distribution Transformers to change the transformer relation. Tensions: 15, 25 KV Nominal current: 30, 60, 250, 350[...] See more
 LINEAL DERIVATION CHANGER